Study at a glance
Summary
Disclaimer: The following summary details independent academic research. Theia3D is intended for research, sports performance and educational use only. It is not cleared as a medical device and is not intended to be used for the diagnosis, treatment, mitigation or prevention of any disease, injury or medical condition.
Editor's note: This paper does not state a specific Theia3D software version or camera brand/model in its methods; it reports only that 9 synchronized video cameras were used. Here, Theia3D served as a post-operative functional assessment tool documenting gait one year after surgery, rather than as a system being validated against marker-based motion capture.
Study Overview
Design
A single case report describing the surgical approach and one-year functional and gait-based outcomes following conversion of a surgically fused knee to a total knee replacement in a young adult.
Case Summary
The individual, a 24-year-old man, sustained an open patella fracture and a serious head trauma in a motor vehicle collision in 2017. Following complications including a persistent, antibiotic-resistant joint infection, his care team elected to surgically fuse the knee in 2018 to resolve the infection and stabilize the joint. Four years later, at age 24, he sought care for poor function and quality of life related to the fused knee. After a thorough work-up ruling out active infection, the surgical team performed a conversion procedure in 2022 involving a tibial tubercle osteotomy, a constrained rotating-hinge knee implant to address ligament insufficiency, and a medial gastrocnemius muscle flap with a skin graft to provide soft-tissue coverage over the new implant.
Gait Assessment
One year after the conversion procedure, the individual underwent a standardized gait assessment: walking barefoot at a self-selected comfortable pace along a 6-meter path, repeated six times with brief rest periods between trials. Movement was captured using 9 synchronized video cameras processed through Theia3D, with joint angles calculated in Visual3D and compared against a normative reference band built from the gait cycles of 18 healthy adults within the system.
Analysis
Standard functional outcome measures, including KOOS, the Western Ontario and McMaster Universities Osteoarthritis Index, a visual pain rating scale, and a general health-related quality-of-life questionnaire, were compared between the pre-operative baseline and the one-year follow-up. Sagittal-plane hip, knee, and ankle joint angle curves from the gait assessment were visually compared, side-to-side and against the normative reference band, to characterize specific movement asymmetries.
Key Findings
- Standard functional outcome measures improved substantially across every domain assessed one year after the conversion procedure, including the Western Ontario and McMaster Universities Osteoarthritis Index (improving from 33 to 1, where lower scores reflect better function) and every KOOS subscale (symptoms improving from 57% to 96%, pain from 75% to 97%, daily function from 49% to 100%, and sports/recreation function from 5% to 90%), alongside pain ratings dropping from 5 to 0 out of 10 and overall health-related quality of life improving from 50% to 100%.
- Markerless gait analysis identified a measurable asymmetry in step timing between the two legs, with the previously fused (left) leg spending more time on the ground during each step than the right leg, though the authors note this pattern can reflect several contributing factors beyond the surgical history alone.
- Left hip flexion was reduced by approximately 10 degrees during the right leg's support phase, and right hip flexion was comparatively insufficient during the left leg's support phase, indicating an imbalance in how the individual transferred weight between legs while walking.
- Left knee flexion during the loading response phase of stance was below the roughly 15 degrees expected in typical gait, a pattern consistent with reports of reduced knee flexion following total knee replacement, particularly with more constrained implant designs like the rotating-hinge prosthesis used in this case.
- The gait assessment also identified a 10-degree active extension lag at the knee, within the range reported for this kind of conversion procedure but noted by the authors as a potential ongoing contributor to altered movement efficiency, which they suggest could help guide continued strength-focused follow-up work.
What This Means for Movement Science Researchers and Orthopedic Outcomes Teams
For researchers and teams working in orthopedic movement assessment, this case report offers a concrete illustration of how markerless motion capture can add a specific, interpretable layer of information to standard outcome questionnaires following a complex orthopedic procedure: the gait assessment surfaced side-to-side asymmetries in hip and knee mechanics that a validated but inherently subjective questionnaire score, however dramatically improved, would not have revealed on its own. The authors are careful to frame this as a single, favorable case rather than a validated predictive tool, but their broader point, that markerless gait analysis can detect subtle, joint-specific kinematic deviations that might otherwise go unnoticed, is a useful illustration of the kind of functional, movement-based follow-up this technology could support in post-operative orthopedic assessment, a use the authors note currently remains largely confined to research settings.
The Role of Theia3D in Movement Analysis
Theia3D served as the post-operative functional gait assessment tool in this case report, capturing joint angle data one year after a conversion knee replacement procedure and comparing it against a built-in normative reference band rather than against a marker-based system within this particular study. This reflects a practical, real-world use case: a markerless setup that required no markers or dedicated motion-capture laboratory time beyond a short walking assessment, applied to document functional recovery after a complex, relatively rare orthopedic procedure.
Study Limitations and Future Directions
The authors are direct about this report's core limitation: it describes a single case with a relatively short, one-year follow-up period, which prevents any conclusion about longer-term implant durability or whether the gait patterns observed will change further over time. They note that the asymmetries identified in the gait assessment cannot be attributed with certainty to any single cause, since prosthetic design, residual muscle weakness, and joint stiffness, among other possible contributing factors, could all plausibly play a role, and that the current use of this kind of markerless gait assessment following complex knee procedures remains largely confined to research settings rather than routine orthopedic follow-up. They identify continued strength-focused follow-up and gait-focused reassessment as reasonable next steps for this individual, and more broadly suggest that applying markerless gait assessment to larger series of this and related procedures would help establish how representative these specific findings are.
Citation: Sirka, A., Lukoseviciute, G., Kadusauskas, T., Daublys, D., Domeika, A., Gudas, R., & Rimkunas, A. (2026). Managing knee arthrodesis conversion to arthroplasty in a young patient: Surgical strategy, challenges, and functional recovery after 1 year. Arthroplasty Today, 37, 101943. https://doi.org/10.1016/j.artd.2025.101943
Link: Read the full study
Can Markerless Gait Analysis Add Insight to Complex Orthopedic Outcome Reporting?
This case report of a young man's conversion from a fused knee to a total knee replacement shows how markerless gait analysis using Theia3D identified specific, interpretable movement asymmetries one year after surgery, complementing the dramatic improvements captured by standard outcome questionnaires. If your work involves post-operative functional assessment and you want to explore how markerless motion capture can add a movement-based layer to outcome reporting, talk to our team about applying Theia3D to your own research.