Study at a glance

In 30 ski jumpers of varying age and competitive level, Theia3D-based markerless motion capture combined with a statistical clustering analysis identified three distinct, biomechanically effective trunk, hip, and knee movement strategies used during the early flight phase immediately after take-off, each achieving jumps that reached or exceeded the hill's K-point.

Summary

Disclaimer: The following summary details independent academic research. Theia3D is intended for research, sports performance and educational use only. It is not cleared as a medical device and is not intended to be used for the diagnosis, treatment, mitigation or prevention of any disease, injury or medical condition.

Editor's note: Theia3D version 2022.0.2309.p20, as stated in the paper. Here, Theia3D served as the motion-capture tool for a research question about early flight movement strategies, rather than as a system being validated against marker-based motion capture within this particular study. The authors note that validation evidence for Theia3D specifically in ski jumping remains limited, and that this sport poses distinctive challenges for markerless tracking.

Study Overview

Design

A cross-sectional biomechanical study using principal component analysis and hierarchical clustering to identify and characterize distinct trunk, hip, and knee movement strategies during the early flight phase of ski jumping.

Participants

Thirty ski jumpers (23 men, 7 women; age 21.5 years; height 167.2 cm; mass 56.4 kg), spanning a broad age range from junior (18 years and younger) to senior (19 years and older) and competing at both national and international levels, with no neuromuscular or musculoskeletal impairment affecting jumping motion.

Data Collection

Data were collected across six sessions between October 2022 and July 2024 at a ski jumping stadium with a K-point of 90 meters, under competition-like conditions on a ceramic in-run track. Participants performed their normal jump routines, with weather conditions and in-run speed not controlled, though in-run speed was separately measured. Movement was captured using ten Sony RX0 II video cameras (120 frames per second, full HD resolution) positioned around a roughly 10-meter section of the hill, processed through Theia3D. Only trials in which the jumper reached at least the K-point were analyzed, with the longest-distance trial used for participants with multiple qualifying trials.

Analysis

Trunk anterior-posterior tilt angle and hip and knee flexion-extension angles were extracted as continuous, time-normalized waveforms from take-off through 0.2 seconds afterward (the early flight phase). Principal component analysis was applied separately to each joint angle's waveform data to reduce its dimensionality while preserving its dominant temporal features, and the resulting principal component scores were combined and subjected to hierarchical clustering to identify distinct movement strategies. Statistical parametric mapping, using a one-way analysis of variance with post hoc pairwise comparisons, was then used to evaluate differences in the original kinematic waveforms between the identified clusters, and in-run speed was compared across clusters to assess whether cluster differences could be explained by approach speed alone.

Key Findings

  • A three-cluster solution was statistically supported, revealing three distinct early flight movement strategies: one defined by a quickly rising trunk paired with rapid hip and knee extension from a shallow starting position, a second defined by a flatter, more compact trunk posture paired with more gradual hip and knee extension from a deeper starting position, and a third, hybrid strategy combining elements of both.
  • Significant differences in trunk, hip, and knee kinematics were found across the three clusters, with post hoc analyses showing that trunk and knee differences were driven primarily by contrasts between the "rising trunk" and "flatter trunk" strategies, while hip kinematics played the central role in distinguishing the third, hybrid strategy from the other two.
  • In-run (approach) speed did not differ significantly between the three clusters, and additional sensitivity analyses confirmed that the pattern of cluster differences in kinematic features was not attributable to differences in approach speed, supporting that the identified strategies reflect genuine differences in movement coordination rather than simply different approach velocities.
  • The hybrid strategy was found across a notably broader mix of ages, sexes, and competitive levels than the other two strategies, one of which consisted exclusively of senior male jumpers, suggesting the hybrid pattern may represent an adaptable movement solution accessible across a wider range of physical maturity and developmental stages.
  • Because all three strategies were used by jumpers whose trials reached or exceeded the hill's K-point, the authors emphasize that their findings describe distinct, biomechanically effective coordination patterns rather than a performance ranking, and that these interpretations are descriptive rather than evidence of a direct causal relationship between a specific movement strategy and jump distance.

What This Means for Movement Science Researchers and Ski Jumping Performance Teams

For researchers and coaching staff working with ski jumpers, this study offers a specific, practically useful reframing of early flight technique: rather than a single ideal posture, multiple distinct trunk, hip, and knee coordination strategies can each produce jumps that reach competitive distance benchmarks. This gives coaches a more nuanced descriptive framework for evaluating an individual athlete's early flight technique, supporting individualized feedback based on which broad strategy an athlete's movement pattern most resembles, rather than measuring every jumper against one prescribed technique. The study's approach also illustrates a broader methodological opportunity for sports biomechanics: combining markerless motion capture's practicality for outdoor, field-based data collection with principal component and clustering analysis to objectively identify movement strategies that might not be apparent from simple group-average comparisons.

The Role of Theia3D in Movement Analysis

Theia3D served as the markerless motion-capture tool in this study, enabling trunk, hip, and knee kinematic measurement during real outdoor ski jumping trials under competition-like conditions, a setting that would present considerable practical challenges for a marker-based approach given the helmets, skis, and loose-fitting snowsuits involved, as well as the outdoor, multi-session data collection spanning nearly two years. The authors note that markerless validation evidence specific to ski jumping remains limited compared to more established tasks like walking and running, and that this sport presents distinctive tracking challenges, including the absence of front-facing camera angles and clothing and equipment that can obscure anatomical landmarks.

Study Limitations and Future Directions

The authors identify an important, Theia3D-specific limitation worth highlighting directly: ankle and upper-limb joints were excluded from this study's analysis based on visual inspection that identified tracking instability and non-physiological noise in those joint angle waveforms under these challenging outdoor field conditions, while the trunk, hip, and knee sagittal-plane kinematics used in the analysis were judged comparatively stable. The authors are explicit that even these retained measures' accuracy "should not be assumed equivalent to laboratory-based marker-based systems," and that their results should be interpreted as movement strategies derived from markerless estimates under realistic field conditions, rather than as definitive representations of true joint kinematics, with further validation studies specific to ski jumping identified as important for strengthening confidence in this kind of analysis. Beyond this, the authors note that their analysis was limited to the right leg only, assuming bilateral symmetry, which precludes assessment of side-to-side asymmetries; that only trials reaching the K-point were included, limiting conclusions about flight stability or landing quality; that environmental factors like wind and in-run speed were not measured or controlled, so cluster differences may partly reflect environmental influences rather than kinematics alone; that the temporal window analyzed was restricted to the first 0.2 seconds of flight due to technical constraints of the field-based measurement setup; and that their sample consisted primarily of Japanese athletes, which may limit generalization to other populations with different anthropometry or coaching systems. The authors identify incorporating additional body segments and kinetic or aerodynamic force measurements, exploring event-based rather than fixed-time movement normalization, and continuing to validate Theia3D specifically within ski jumping contexts as important next steps.

Citation: Ueno, T., Ishihara, T., & Yamamoto, K. (2026). Identification and classification of kinematically effective early flight postures in ski jumping. Sports Biomechanics. Advance online publication. https://doi.org/10.1080/14763141.2026.2649472

Link: Read the full study

Are There Multiple Effective Early Flight Techniques in Ski Jumping?

This study of 30 ski jumpers uses Theia3D markerless motion capture combined with a statistical clustering analysis to identify three distinct, equally viable trunk, hip, and knee movement strategies used during the critical early flight phase immediately after take-off. If your work involves ski jumping or winter sports performance research, talk to our team about applying Theia3D to your own studies.

Recent Posts